Print Room HQ Setup guide Download the beta

Air quality monitor (Panda Sense Pro)

Print Room HQ reads a BIGTREETECH Panda Sense Pro directly over your Wi-Fi and shows the room’s air on the Live page. Each print keeps a record of what it did to the air, and you get an alert if the air stays bad.

In Print Room HQ: Settings › Print room › Sensors

What you need

  • A BIGTREETECH (BIQU) Panda Sense Pro, set up on your Wi-Fi.
  • Its IP address, shown on its own screen once it’s connected.

Connect it

  1. Get the sensor on Wi-Fi using its own setup, and note the IP address on its screen.
  2. Reserve that address in your router so it never changes. Most router apps call it a DHCP reservation or Reserve IP.
  3. Open Settings › Print room › Sensors, enter the IP address under Air quality monitor (Panda Sense Pro), give it a Name, and click Save. The status line changes to “Connected, waiting for the first reading…”, then shows Good, Fair or Poor air.

It connects over MQTT on port 1883, on your network only. Nothing goes through the cloud.

The first two days

The VOC and formaldehyde parts of a new sensor swing a lot while they burn in. For the first 48 hours those two readings won’t trigger alerts, prints made during that time are left out of Fumes by material, and the dashboard shows “Settling in”. Particle readings count right away.

Alerts

Alert me when the air stays poor for 5 minutes is on by default. Poor means PM2.5 over 35 µg/m³, VOCs over 1.0 mg/m³, formaldehyde over 0.1 mg/m³ or CO₂ over 1500 ppm. It repeats at most every 6 hours, and you get a note when the air is back to normal.

CO₂ climbs with people in a closed room, not from printing. The VOC number is an estimate, so watch the trend and compare prints with each other rather than treating it as an exposure number.

What you get

  • An air row at the top of the Live page that grows into a full tile when something needs attention.
  • A room page with the last 24 hours, the last 30 days, and Fumes by material.
  • Air during this print in History: the peak and average while each print ran, and a minute-by-minute curve from 15 minutes before to 30 minutes after.
  • The sensor’s own settings page (brightness, screensaver, firmware, Wi-Fi) through Open its settings page ↗, from any device that can reach Print Room HQ.
  • A notice when BIGTREETECH publishes new firmware. Nothing installs on its own; you install it from the sensor’s page.

If something’s not right

“Can’t reach (address):1883.”

Check the IP on the sensor’s screen. If it changed, enter the new one, and reserve it in your router so it doesn’t change again.

Readings come in, but its settings page won’t open

The sensor’s little web server can get stuck while the readings keep working. Unplug the sensor for 10 seconds and plug it back in.

VOCs are high with nothing printing

Cleaners, IPA, glue or paint nearby will do it. If the number sits at the same high value day and night and never moves during prints, contact BIGTREETECH; that points to a faulty VOC sensor.